Pancake load cells.
Precision starts
with the load path.
Low-profile compression & tension force transducers for material testing, servo press-fit systems and structural rigs. Align the capacity, bolt circle and measurement chain before you commit.
Same low profile.
Five different engineering briefs.
Select by force direction, fixture interface and duty cycle. Listed ranges define the requested family envelope; available combinations are confirmed in the quotation.
Universal tension & compression
UTM frames · servo cylinders · structural testing
1–500 kNExplore configuration01 ↗MT-PLC-12011201-style compression
Servo press-fit · die closure · hydraulic press monitoring
2–1,000 kNExplore configuration02 ↗MT-PLC-32013201-style stainless steel
Outdoor test rigs · reactor vessels · humid process equipment
2.5–500 kNExplore configuration03 ↗MT-PLC-FLGFlange-to-flange
Compact test fixtures · robot flange axial loads · automation tooling
500 N–100 kNExplore configuration04 ↗MT-PLC-12-FAT / MT-PLC-12-DBFatigue & dual bridge
Aerospace structural rigs · component endurance · cyclic materials tests
Capacity and fatigue envelope reviewed per projectExplore configuration05 ↗A familiar model number
is only the starting point.
Review an Interface 1200 / 1201 / 3201 or HBK U10M alternative through a documented mechanical and electrical comparison.
OD. Height. Thread. Bolt circle.
Capture the original drawing revision, installed base and loading hardware. Check the complete stack, not just the sensor body.
Bridge output to system scaling.
Compare excitation, mV/V, polarity, pinout and the receiving amplifier. Plan recalibration after replacement.
Static accuracy and dynamic duty.
Confirm overload, parasitic loads, stiffness and the force spectrum. Keep a measured acceptance plan with the replacement record.
The base is part of
the measuring system.
Support stiffness, bolt preload and contact alignment influence the force seen by the sensing webs. A low-profile compression force transducer needs a controlled installation boundary.
Ground mating base
Include the intended mounting base in the dimensional and calibration review.
Spherical contact, controlled alignment
Review button radius, platen hardness and lateral freedom under load.
One defined measurement chain
Specify bridge, excitation, amplifier, sampling and traceability as one system.
Bring the load path.
We’ll review the fit.
Send your capacity, center thread and mounting envelope. Include the full original part number when replacing an installed sensor.
CAD and test reports are supplied for the agreed configuration. No generic drawing is presented as an approved production part.
Published and reviewed 2026-10-27 · Responsible publisher: Magatom Dynamics Co., Ltd.